5.9Medium

CVE-2026-13217

The OCPP 1.6 client in subsys/net/lib/ocpp/ocpp.c reconstructs a session handle and PDU id from the uid field of a CALLRESULT message. In ocpp_process_server_msg() the code calls atoi(strtok_r(uid, "-", &tmp)) without checking the strtok_r return value. When the server-supplied uid is empty or contains no - delimiter, strtok_r() returns NULL and atoi(NULL) dereferences a NULL pointer, which is undefined behaviour. The uid originates from network data: parse_rpc_msg() in subsys/net/lib/ocpp/ocpp_j.c JSON-parses a frame received from the OCPP central system over TCP/WebSocket and copies the server-controlled string into the local buffer. A malicious or compromised central system, or a man-in-the-middle on a non-TLS ws:// connection, can return a malformed uid to reach the defect. No authentication beyond the existing server connection (or MITM position) is required, and the reconstructed pointer is membership-validated by ocpp_session_is_valid(), so the impact is limited to the NULL dereference rather than arbitrary pointer use. On Zephyr targets that trap access to address 0 (MMU/MPU platforms or CONFIG_NULL_POINTER_EXCEPTION_DETECTION), the dereference faults inside the OCPP reader thread and invokes the fatal handler, producing a remote denial of service of the charge point; on bare targets where address 0 is readable the call returns 0 and is benign, so the impact is availability-only and platform-conditional. The applied fix guards only the first atoi(); the second strtok_r(NULL, "-", &tmp) followed by pdu = atoi(buf) in the same function remains unguarded and the identical NULL dereference is still reachable from the same network input when the uid has a first token but no second --delimited token. A complete fix should validate the second token as well.

What this means for your business

  • An attacker can use it remotely, over a network, without a login, and without anyone at your company clicking anything.
  • FIRST's prediction model gives it a 0.5% chance of attack attempts being seen in the next 30 days, ranking above 42% of all known flaws.

What to do

  1. 1Ask your IT team or provider whether any of your systems use the affected product.
  2. 2If you do, follow the vendor's guidance. No patch reference has been published yet.

Not sure if your company is exposed?

Fastnexa’s certified penetration testers can check whether attackers could use this flaw, or others like it, against your websites, apps and network. The full test is free for our first 10 founding clients until 31 December 2026.

Scoring

CVSS
5.9 (v3.1)
Vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-476
Assigned by
vulnerabilities@zephyrproject.org

Dates

Published
2026-08-25
Last modified
2026-08-26
Sources
NVD